| J Adv Prosthodont. 2013 Aug;5(3):326-332. English. Published online Aug 31, 2013. https://doi.org/10.4047/jap.2013.5.3.326 | |
| © 2013 The Korean Academy of Prosthodontics | |
|
Young-Seok Park, DDS, MS, PhD,1
and Ho-Beom Kwon, DDS, MS, PhD | |
|
1Department of Oral Anatomy and Dental Research Institute, School of Dentistry, Seoul National University, Seoul, Republic of Korea. | |
|
2Department of Prosthodontics and Dental Research Institute, School of Dentistry, Seoul National University, Seoul, Republic of Korea. | |
| Received April 19, 2013; Revised August 03, 2013; Accepted August 13, 2013. | |
|
This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by- | |
This article has been cited by 5 articles in This article has been cited by Google Scholar. This article has been cited by 1 article in PubMed Central. This article has been cited by 10 articles in Scopus. This article has been cited by 7 articles in Web of Science. | |
|
Abstract
| |
|
PURPOSE
The purpose of this study was to compare stress distributions of implant-supported crown placed in fibula bone model with those in intact mandible model using three-dimensional finite element analysis.
MATERIALS AND METHODS
Two three-dimensional finite element models were created to analyze biomechanical behaviors of implant-supported crowns placed in intact mandible and fibula model. The finite element models were generated from patient's computed tomography data. The model for grafted fibula was composed of fibula block, dental implant system, and implant-supported crown. In the mandible model, same components with identical geometries with the fibula model were used except that the mandible replaced the fibula. Vertical and oblique loadings were applied on the crowns. The highest von Mises stresses were investigated and stress distributions of the two models were analyzed.
RESULTS
Overall stress distributions in the two models were similar. The highest von Mises stress values were higher in the mandible model than in the fibula model. In the individual prosthodontic components there was no prominent difference between models. The stress concentrations occurred in cortical bones in both models and the effect of bicortical anchorage could be found in the fibula model.
CONCLUSION
Using finite element analysis it was shown that the implant-supported crown placed in free fibula graft might function successfully in terms of biomechanical behavior. |
|
Keywords:
Finite element analysis; Mandibular reconstruction; Hemimandibulectomy; Fibula
|
|
|
INTRODUCTION
|
When oral cancer involves tongue and floor of the mouth, surgical resection has been the choice of treatment.1 Surgical resections frequently involve mandible and this ablative surgery usually leads to impaired oral functions, as structures related to oral functions can be damaged. Altered oral anatomy, unbalanced and impaired muscles, the limitation of jaw movement and the existence of scar tissues influence patients' speech, swallowing and mastication function as well as esthetics.1 Although rehabilitation using surgical and prosthodontic methods has been improved, patients still seem to have postoperative difficulties in restoring oral function to presurgical level.2 Before introduction of free flap reconstruction after mandibulectomy, postoperative impairments of oral functions were worse, and subsequent prosthodontic treatments were very challenging to prosthodontist because of the lack of bony foundation and deformation of supporting tissues.3
Recently free-flap reconstruction seems to be the best treatment option and become the standard of treatment after mandibulectomy.4, 5 The fibula has been thought of to be reliable after mandibulectomy in terms of providing good functional and esthetic results.6-8 It was reported that it can provide large quantity of bone and good vascularization, has good quality bone, might be contoured into various shape, and can give excellent esthetic results.4, 6, 9
With the advent of osseointegrated implants, fibula free graft can be more suitable for achieving optimum prosthodontic goals using both removable and fixed prostheses.6-8 The reconstruction using osseointegrated implant on free fibula graft after mandibulectomy enhanced the results of prosthodontic treatment.10 It was reported that using these combined treatment, patients' postoperative oral function reached a reasonable level, postoperative complications were greatly reduced, the quality of life has been improved.6, 11
However, there are shortcomings for the treatment using free fibula graft and osseointegrated implant. Because dimension of fibula is usually smaller than the mandible, it is not possible to restore alveolar height using fibula.12 When the contralateral side of the mandible is intact, this problem is important. As a result, when dental implants were placed, undesirable implant-crown ratio could be found. Although techniques such as a double-barrel fibula graft or high position of fibula were suggested,13, 14 the possibility of unfavorable aspects in terms of biomechanics cannot always be ignored in patient's mandibular reconstruction. Biomechanical analysis for the mandibular reconstruction is necessary because the evaluation on the quality and quantity of bone are important for proper function of osseointegrated implant,15 and complications including implant failure and component fracture can occur in both grafted bone and the intact mandible.16 Because geometry of the model as well as the property of the material is important in biomechanical behavior,17 biomechanical analysis of the implant-supported crown in fibula which has different geometry from mandible, usually unfavorable spatial relation, would be meaningful.
Although there are several known biomechanical analysis methods, most of them are usually difficult to be performed in clinical situation because of the difficulty of application methods. Finite element analysis has been used in dentistry to evaluate implant designs and factors related to the success of implant.18 Finite element analysis has advantages in investigating complex structures such as dental implant or human maxillofacial area. There have been many biomechanical studies using finite element analysis on the osseointegratedimplant on the intact mandible.19-21 However, it is not easy to find the biomechanical study on dental implant in fibula, which has a different geometry from the intact mandible. The purpose of this study was to compare biomechanical behaviors of implant-supported crown placed in fibula bone model with the implant-supported crown in intact mandible model using three-dimensional finite element analysis.
|
MATERIALS AND METHODS
|
Two three-dimensional finite element models were created to simulate implant-supported crowns placed in intact mandible and grafted fibula. The geometries of mandible and fibula were obtained from the patient's computed tomography (CT) data. The patient was 20 year old female and had undergone hemimandibulectomy and reconstruction with fibula-containing free flap for the treatment of fibrosarcoma. Using segmentation software (Amira, Viwage Imaging Inc., San Diego, CA, USA) the geometries of fibula and mandible were extracted from the raw CT data. Geometries were exported into meshing program (Visual-Mesh, ESI group, Paris, France), and then tetrahedral volumetric meshes of normal mandible and grafted fibula were generated. For the finite element model of this study, segment of the fibula including mandibular first molar position was used. The length of the fibula segment used was 40 mm mesiodistally. Meshes of dental implant system with external hexagon (Osstem US system, Osstem Implant Co., Busan, Korea) were created and placed in the middle of bone model. The dimension of implant was 10 mm in length and 4 mm in diameter. All of the implant components including abutment and abutment screw were designed separately (Fig. 1). Some parts of the implant components including abutment screw were simplified for the reduction of calculation time. Crown meshes were created considering opposing maxillary dentition. The height of crown was about 14 mm. For the intact mandible model, normal mandible segment in the contralateral side with the same mesiodistaldimension was mirrored, was modified into edentulous mandible, and replaced the fibula bone model (Fig. 2). Except for bone meshes, meshes for other components were identical in both models. The total numbers of nodes and finite elements were 39,365 and 118,594 respectively for the mandible model and 32,570 and 80,189 respectively for the fibula model.
|
|
In the two models, the implants were assumed to be attached to cancellous bones and cortical bones to simulate a complete osseointegration. In addition, abutment and crown were firmly attached to each other, and the thread portion of the abutment screw was attached to the screw hole of the implant fixture. Contact interfaces were set on the mating surfaces between the inferior surface of abutment and top of the fixture, and between the inferior surface of abutment screw head and abutment. The coefficient of friction values of 0.16 from the previous study was used for the contact between abutment and implant.22 For the contact between the abutment screw and abutment the friction coefficient of 0.2 was used.22 The nodes in the medial and distal ends of the models were constrained in all directions. Assumptions were made that all materials in the models were homogenous, isotropic, and linearly elastic. The material properties of the elements were originated from the previous studies and are represented in Table 1.23, 24
|
Based on the previous study, 50 N vertical force, 150 N vertical force and 50 N oblique force were used to simulate masticatory loading.25, 26 Loads were evenly distributed on the buccal portion of the crown. Oblique loads were applied on the same area with vertical force and were at a 45 degrees angle to the long axis of the implant in buccolingual direction. Comparisons of stress distributions were performed using measurements of the maximum von Mises stress values and analyzing contour plots of the von Mises stresses. The protocols and procedures of the study were reviewed and approved by the Institutional Review Board at the Seoul National University Dental Hospital.
|
RESULTS
|
The highest stress concentrations were observed in the top of fixture and the inferior surface of abutment in all models. However, positions of stress concentrations were different based on the models. In the mandible model, highest stress concentrations occurred in the distolingual area on the top of the fixture. In contrast, in the fibula model, the high stress concentrations were located in the buccal and mesial area of the top of the fixture (Fig. 3). In case of oblique load, overall stress distributions were similar in the two models, however, they were different from those with vertical loadings.
|
In all models, the highest von Mises stress value was found in the implant body. With vertical loads of 50 N, the highest von Mises stress values in the intact mandible models was 612.19 MPa. It was higher than in the fibula model (605.47 MPa). With vertical loads of 150 N, the highest von Mises stress value of the mandible model (612.20 MPa) was higher than that in the fibula model (606.28 MPa). With oblique loading, the highest von Mises stress values were higher than that with vertical loadings, and the same tendency of higher stresses in mandible model was observed (Table 2).
|
In the individual prosthodontic components there was no prominent difference between models. The highest von Mises stress value of the abutment in the fibula model was similar to that in the mandible model (Table 3). Fig. 4 describes stress distributions of the implant components in the models with vertical force of 150 N.
|
|
In the bone, the highest von Mises stress values were much higher in the cortical bone than in the cancellous bone. In the cancellous bone, all models showed similar values (Table 4). In the cortical bone, the highest von Mises stress values in the fibula model was lower than that in the intact mandible model with vertical loading, and the increase of load intensity from 50 N to 150 N did not produce noticeable difference. With oblique loading the highest von Mises values were similar in the two models. In the bone, overall stress distributions in two modes were similar and the change of loading condition influenced the stress distribution on the cortical bone layer (Fig. 5). In the fibula bone model, the effect of bicortical anchorage could be found (Fig. 5).
|
|
The maximum displacement values of the models are shown in Table 5. The highest displacement value was obtained in the mandible model with oblique loading. The maximum displacements in all models were found in the interface between fixture and cortical bone.
|
|
DISCUSSION
|
In this study it has been shown that the fibula bone graft might not be disadvantageous for the rehabilitation using dental implant after hemimandibulectomy in terms of stress distribution. There was no prominent stress peak in the fibula bone model and stress concentration levels of the fibula model were similar to those in the mandible model. Although the von Mises stress contour of the implant components showed that the stress distribution of the two models were not identical, the stress distribution of the fibula was not unfavorable. This result was in accordance with clinical results using fibula graft and osseointegrated implants. The implant survival rate after mandibular reconstruction is known to be high and reported to range from about 85% to 100%.27-30 These high survival rates showed that implants in fibula might be stabilized biomechanically.
Because the geometries of the two models were identical except for bone parts, the difference in geometries and material properties of the bones might play a role in the difference of stress distribution. In this study, Young's modulus of the cancellous bone in fibula was lower than that of the mandible. However, the values of von Mises stresses in the cancellous bone were relatively small, and it seems that the influence of the cancellous bone was weak. Thus, the differences in the results may originate from the difference in the cortical bone layers. The thick cortical layer of fibula is thought to be the cause of the favorable results in the fibula model. It was previously reported that the cortical bone thickness that supports the implant fixture is important factors in osseointegration including the initial stability of implant, because thick cortical bone can contribute to the fixation of implant.31 The fibula was reported to have a thick cortical bone about 3.5 mm.32 Although it was reported in the same study that the fibula had lowest bone density among possible donor bones after maxillofacial resective surgery, the fibula was also reported to have relatively high bone-implant interfacedensity.32 In another studies the importance of cortical bone thickness was stressed. It was stated that implant is supported by cortical bone in terms of biomechanical view16 and bone quality and quantity could influence on the stress of osseointegrated implants.33, 34 On the reason how thick cortical bone is advantageous in the initial stabilization of the implant, it was explained that thick cortical bone could reduce micromovements of the implant, and during functional period of implant, better stress distributions can be maintained.35-37 In another study it was stated that the presence of dense bone is the prerequisites for predictable osseointegration.38 In a study using finite element analysis it was shown that maximum stresses occurred in the cortical bone and thicker cortical bone reduced stress levels.39 In this study the von Mises stress values in the cortical bone of the fibula model with vertical loading were lower than those in the mandible model. This might be dueg to the thick cortical bone layer in fibula model. As the geometries used in this study including cortical bone thickness were extracted from patient's CT data, these results appeared to be realistic.
In addition to the thickness of cortical bone, bicortical anchorage can be a factor to explain the favorable results in the fibula model. In this study the fibula model showed that the stress concentration occurred in lower cortical layer of the fibula. This result is in accordance with the previous reports. In a previous study using finite element analysis bicortical anchorage reduced the peak stress in cortical and cancellous bone.40 In another study measured the removal torque it was reported that the removal torque was higher for the bicortical implants than for the monocortical ones. In a study using finite element analysis bicortical anchorage was reported to improve initial stability of the implant.41 In this study bicortical anchorage of the implant in the fibula model was thought to contribute to the favorable results. However, it was stated that bicortical anchorage might not be related with the reduction of the risk of marginal bone loss because it has little influence on the displacement of coronal part of the implant.42 Although the maximum displacement in the fibula model was smaller than in the mandible model in this study, further study is required to evaluate the contribution of bicortical anchorage on the marginal bone loss. Quantitative considerations on factors including dynamic nature of masticatory force, the influence of implant-crown ratio,the limitation of mandibular motion, muscular imbalance, and quantity of offset load from unfavorable maxillomandibular relationship are required in mandibular reconstruction patients. In this study to analyze the difference of the mandible and the fibula, same components were used except for the bone meshes. Although patients' original vertical dimensions can be reduced intentionally with the limited mouth opening and for more favorable biomechanical results, crown length of the implant-supported prosthesis in the fibula is usually longer than that in the mandible and this might produce unfavorable biomechanical situation. Further quantitative studies are required for analyzing the effect of the various crown length of the implant-supported prosthesis in the fibula graft model.
In the present study contact condition was included between abutment and fixture, and abutment screw and abutment for the more precise prediction of models. This setting of contact condition seemed to contribute to the production of precise results. Although finite element analysis is a method for obtaining a solution by dividing objects into a small elements and it is the most suitable to oral and maxillofacial area which has highly complex geometries, many simplifications and assumptions in terms of detailed geometry, material properties, boundary conditions, and the interface between the bone and implant are included in finite element analysis.18 In future studies using finite element analysis consideration of interaction between components including stretching of abutment screw, component misfit, and description of incomplete osseointegration would produce more predictable results.
|
CONCLUSION
|
In this study using finite element analysis the stress distributions in the fibula models were comparable to those in the mandible model. The osseointegrated implants used with the fibula free flap reconstruction might be expected to have predictable biomechanical behavior in their function.
|
Notes
|
This study was supported by grant no. 04-2010-0043 from the SNUDH Research Fund.
|
References
|